Self-Adhesive Fire Tape
Fire
Rated for
1-Hour Walls
E-Z Fire Tape has passed the full scale tests*
for one-hour fire rated, vertically or
horizontally hung wall systems, on both wood
and steel stud construction with fire rated
gypsum board. E-Z Fire Tape is not rated for ceilings.
E-Z Fire Tape has been rated for use in Fire Wall construction in Canada by Intertek Testing Service since 2002.
Tested to meet UBC Standard 7-1-1994, ASTM E119,
CAN/ULC-S101, NFPA 251 and UL 263 procedures. The test assembly was conducted according to both U 465
and GA 1200 design. Listed by ICC Evaluation Services, Inc. Report
ESR-1231. (Testing conducted by Intertek Testing Services (Warnock-Hersey) 1995)
Now Fire Rated
for 2-Hour Walls
E-Z Fire Tape is listed by
Intertek Testing Services (Warnock-Hersey) for two-hour fire rated, vertically or horizontally hung wall systems, on both wood and steel stud construction with fire rated gypsum board. E-Z Fire Tape is not rated for ceilings.
The listing is based on tests that were conducted to
meet UBC Standard 7-1-1994, ASTM E119,
CAN/ULC-S101, NFPA 251 and
U 263 procedures. The test assembly was constructed according to both U 465
and GA 1200 design
US Patent No. 5.486.394, 5.687.523, and
6.226.946
Foreign Patents Pending
Made in U.S.A. |
|
|
|
|
© E-Z Taping Systems, Inc.
Virtualtech Website Design and Promotion |
|